OAK

요추부 협착에서의 피질골 궤도 나사못 고정의 초기 실패 사례에 대한 고찰

Metadata Downloads
제목
Early Failure of Cortical-Bone Screw Fixation in the Lumbar Spinal Stenosis
저자
권지원 ; 김진규 ; 하중원 ; 문성환 ; 이환모 ; 박융
키워드 (국문)
조기실패피질골궤도나사못척추경나사못요추부척추협착
키워드 (영문)
early failurecortical trajectory bone screwpedicle screwslumbar spinal stenosistraditional medicinemedicinesurgeryscrew fixationpedicle screwcortical bone
발행연도
2020-10
발행기관
대한정형외과학회
유형
Article
초록
Purpose : Pedicle screw insertion has been traditionally used as a surgical treatment for degenerative lumbar spine disease. As an alternative, the cortical-bone trajectory screw allows less invasive posterior lumbar fixation and excellent mechanical stability, as reported in several biomechanical studies. This study evaluated the clinical and radiological results of a case of early failure of cortical-bone screw fixation in posterior fixation and union after posterior decompression.

Materials and Methods : This study examined 311 patients who underwent surgical treatment from 2013 to 2018 using cortical orbital screws as an alternative to traditional pedicle screw fixation for degenerative spinal stenosis and anterior spine dislocation of the lumbar spine. Early fixation failure after surgery was defined as fixation failure, such as loosening, pull-out, and breakage of the screw on computed tomography (CT) and radiographs at a follow-up of six months.

Results : Early fixation failure occurred in 46 out of 311 cases (14.8%), screw loosening in 46 cases (14.8%), pull-out in 12 cases (3.9%), and breakage in four cases (1.3%). An analysis of the site where the fixation failure occurred revealed the following, L1 in seven cases (15.2%), L2 in three cases (6.5%), L3 in four cases (8.7%), L4 in four cases (8.7%), L5 in four cases (8.7%), and S1 in 24 cases (52.2%). Among the distal cortical bone screws, fixation failures such as loosening, pull-out, and breakage occurred mainly in the S1 screws.

Conclusion : Cortical-bone trajectory screw fixation may be an alternative with comparable clinical outcomes or fewer complications compared to conventional pedicle screw fixation. On the other hand, in case with osteoporosis and no anterior support structure particularly at L5-S1 fusion sites were observed to have result of premature fixation failures such as relaxation, pull-out, and breakage.
저널명
대한정형외과학회지
저널정보
(2020-10). 대한정형외과학회지, Vol.55(5), 405–410
ISSN
1226-2102
DOI
10.4055/jkoa.2020.55.5.405
연구주제분류:
NHIMC 학술성과 > 1. 학술논문
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Loading...