Introduction

Clinical decisions in chronic obstructive pulmonary disease (COPD) treatment often utilize serially assessed physiologic parameters and biomarkers. To better understand the reliability of these tests, we evaluated changes in commonly assessed biomarkers over 3 months in patients with clinically stable COPD.

Methods

We performed an observational prospective cohort study of 89 individuals with clinically stable COPD, defined as no exacerbation history within 3 months of enrollment. Biomarkers included lung function and functional performance status, patient-reported outcomes of symptoms and health status, and blood markers of inflammation. The correlation between testing at baseline and at 3-month follow-up was reported as the intraclass correlation coefficient (ICC). "Outliers" had significant variability between tests, defined as >1.645 standard deviations between the two measurements. Differences in clinical features between outliers and others were compared.

Results

Participants with COPD (n = 89) were 70.5 ± 6.7 years old, 54 (61%) male, had a 40 pack-year smoking history with 24.7% being current smokers, and postbronchodilator forced expiratory volume in one second (FEV1) 62.3 ± 22.7% predicted. The biomarkers with excellent agreement between the initial and the follow-up measurements were FEV1 (ICC = 0.96), Saint George's Respiratory Questionnaire (SGRQ) (ICC = 0.98), COPD Assessment Test (CAT) (ICC = 0.93) and C-reactive protein (CRP) (ICC = 0.90). By contrast, parameters showing less robust agreement were 6-minute walking distance (ICC = 0.75), eosinophil count (ICC = 0.77), erythrocyte sedimentation rate (ICC = 0.75) and white blood cell count (ICC = 0.48). Individuals with greater variability in biomarkers reported chronic bronchitis more often and had higher baseline SGRQ and CAT scores.

Conclusion

Our study evaluated the stability of commonly assessed biomarkers in clinically stable COPD and showed excellent agreement between baseline and three-month follow-up values for FEV1, SGRQ, CAT and CRP. Individuals with chronic bronchitis and more symptomatic disease at baseline demonstrated greater variability in 3-month interval biomarkers.


© 2023 Park et al. From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
저널명
International Journal of Chronic Obstructive Pulmonary Disease
저널정보
(2023-07). International Journal of Chronic Obstructive Pulmonary Disease, Vol.18(18), 1475–1486
ISSN
1176-9106
EISSN
1178-2005
DOI
10.2147/COPD.S396549. eCollection 2023
연구주제분류:
NHIMC 학술성과 > 1. 학술논문
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Loading...